Our Capabilities

Telcron connects technology manufacturers with test labs that are proficient in their testing needs. Since many standards tend to be written for several product categories, it’s important to distill these standards into modules that apply to specific product groups – to simplify the project scoping process into manageable chunks for the manufacturer and the lab. Manufacturers can then choose to work with labs that are proficient in each relevant area. 

For instance, a breakdown of tests applicable to a 13.56 MHz Radio Frequency Identification (RFID) reader has been done below to FCC Part 15/RSS 210, UL/CSA 60950-1, and harmonized EU standards. Each of the broken down modules are likely to be completed within a half hour to four hours per product operating mode under normal circumstances in planning a test program. It’s possible that not all of these tests apply to each RFID product due to design variations. Product design documentation may need to be reviewed as part of the compliance effort. A manufacturer can hypothetically select lab ABC to satisfy the North American FCC/IC test requirements chunk and lab XYZ to satisfy the North American UL/cUL and European CE test requirements chunk.

Region

Test Type

Test Category

Applicable Req (s)

Key

 

NORTH AMERICA (FCC/IC)

 

 

 

NAM

Radiated Emissions <30 MHz, TX + sidebands mask

FCC/IC, Emissions

15.225, 15.209/RSS 210

 

NAM

Radiated Emissions >30 MHz (Digital Circuitry)

FCC/IC, Emissions

15.109, RSS 210

 

NAM

Radiated Emissions >30 MHz (TX Spurious)

FCC/IC, Emissions

15.209, RSS 210

 

NAM

Emissions Bandwidth

FCC/IC, Emissions

15.225, RSS 210

 

NAM

Frequency Stability

FCC/IC, Emissions

15.225, RSS 210

 

NAM

Conducted Emissions <30 MHz

FCC/IC, Emissions

15.207, RSS 210

 

 

EUROPE (CE – Mark)

 

 

 

EUR

Radiated Emissions <30 MHz, TX + sidebands mask

CE-Emissions

EN 300 330-1,2

 

EUR

Radiated Emissions >30 MHz (Digital Circuitry)

CE-Emissions

EN 300 330-1,2

 

EUR

Radiated Emissions >30 MHz (TX Spurious)

CE-Emissions

EN 300 330-1,2

 

EUR

Conducted Emissions <30 MHz

CE-Emissions

EN 300 330-1,2

 

EUR

Extreme Voltage & Temperatures

CE-Emissions

EN 300 330-1,2

 

EUR

Conducted noise on Telco Ports

CE-Emissions

EN 300 330-1,2

 

EUR

Receiver Requirements

CE-Emissions

EN 300 330-1,2

 

EUR

Harmonics

CE-Emissions

EN 61000-3-2 | EN 301 489

 

EUR

Flicker

CE-Emissions

EN 61000-3-3 | EN 301 489

 

 

EUROPE (CE – Mark)

 

 

 

EUR

ESD

CE-Immunity

EN 61000-4-2 | EN 301 489

 

EUR

EFT

CE-Immunity

EN 61000-4-3 | EN 301 489

 

EUR

Radiated Immunity

CE-Immunity

EN 61000-4-4 | EN 301 489

 

EUR

Surge

CE-Immunity

EN 61000-4-5 | EN 301 489

 

EUR

Conducted Immunity

CE-Immunity

EN 61000-4-6 | EN 301 489

 

EUR

Voltage Dips & Interrupts

CE-Immunity

EN 61000-4-11 | EN 301 489

 

 

NORTH AMERICA (UL/cUL) | EUROPE (CE – Mark)

 

 

 

NAM+EUR

AC Leakage (Touch Currents)

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Protective Earthing (Grounding Integrity)

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Thermal Test including blocked ventilation

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Input Power Current, VA, Power Factor

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Spacings & Separations Evaluation (wiring & mains
circuit boards)

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Mains Capacitive Discharge

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Permanence of Markings

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Structure rigidity and impact testing

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Label Compliance review

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Sharp Edge Test

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Enclosure Mounting Security Test

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

AC Circuit Short Circuit Evaluation

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

DC Circuit Short Circuit Evaluation

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

High Humidity Dielectric Strength (48 hour soak required)

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Product Cleaning Tests

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Stability & Drop Tests

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Spillage Test

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Container/Compartment Overflow Test

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Internal flow path leakage

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Hazards relating to gasses, dusts, flammable materials testing

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Heater control failure

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Radiation source testing

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Motor, transformer, testing/construction review

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Plastic flammability testing

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Telephone Networks Testing (all of Section 6 of the Standard)

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

NAM+EUR

Connected Networks Testing (all of Section 7 of the Standard)

UL/cUL/CE-Safety

UL/CSA/EN 60950-1

 

 

EUROPE (CE-Mark)

 

 

 

EUR

H – Field

CE-RF Exposure

EN 50364 (SubClause 5.1)

 

EUR

E – Field

CE-RF Exposure

EN 50364 (SubClause 5.1)

 

EUR

Contact Current

CE-RF Exposure

EN 50364 (SubClause 5.2)